152 Necessary works after replacing the frame Chapter 6 RR11R 2-1-2. How to operate The following is an example of setting the frame type to "Cap". (1) To open screen (2) To select the frame (3) To execute Frame Origin Memory (The below message will not be displayed for L-spec. machine.) The following message will be displayed only when "Frame origin memory with the power ON" is set to "YES".(p.159) To set frame type to "A. Clamp T" or "A. Clamp", follow the procedure below. Single-head machine is displayed as "A. Clamp T". Two or more head machine is displayed as "A. Clamp". (L-spec. machine is not available.) In case of two or more head machine, the upper limit value of RPM is limited as follows. Maximum RPM (C-1): 800 rpm Minimum RPM (F2-1): 500 rpm To execute "Frame Origin Memory", follow the procedure below. The frame could hit the machine depending on the frame position and it might cause the damage of the parts. 7 Frame Type Cap Pressing SET key will move the frame. Frame origin memory "YES" >> SET is executed. ! CAUTION