Service Documents

MX INSTRUCTION

Issue link: https://docs.hic.us/i/445631

Contents of this Issue

Navigation

Page 249 of 263

237 Spec. of the machine Chapter 11 1 2 3 4 5 6 7 8 9 10 11 QS10 1-3. Switching of input voltage (some spec. only) The following label (either of one) is stuck at the lower part of the power supply card. Only the model on which label No.3 is stuck can switch input voltage. However, since the setting is performed according to your voltage spec. at shipment, it is not necessary to switch input voltage in usual usage. Perform switching of input voltage only in the following condition. (a) When the machine was moved for installation to the place whose voltage spec. is different from that at shipment (b) When you replace power supply card and connection of the connector CN11 is different from your voltage spec. 1-3-1. How to switch In case of TFMX-C single-head machine and TWMX-C models (1) Detach the stand cover. (2) Change connection of the connector CN11 on the power supply card. Since there could be danger of electric shock, perform the work after turning OFF the power. Exclusive for single-phase/100 V Label No.1 For 3-phase/200 V Single-phase 100 V or 200 V Label No.2 Label No.3 ! DANGER CN11 Label No.3 [Connection of CN11] In case of 100 V series In case of 200 V series Power supply card Stand cover TFMX-C single-head machine CN11 Label No.3 [Connection of CN11] In case of 100 V series In case of 200 V series Power supply card TWMX-C