Page 34 of 247

How to use each part 22 Chapter 2 QS07 2-5. Main shaft handle, Color change handle (Single-head machine only) 2-5-1. Color change handle Turning this handle by hand will cause the needle bar case to slide. It is possible to slide the needle bar case only when the main shaft angle is set to the fixed position. Fix the handle at the position where the screw faces directly above (odd-numbered needle) or directly below (even-numbered needle). 2-5-2. Main shaft handle Turning this handle by hand will cause the needle bar to lower. When turning this handle with the power ON, follow the procedure below. (1) Press F3 key while pressing SET key. (2) Select "2 Weak brake", and press Set key. (3) Select "NO" in the below screen, and press SET key. Main shaft handle Color change handle Screw NO 100 YES / NO/ Always NO [ ] NO Current main shaft angle 2 Weak brake SET F3 +