Functions that must be used practically 29 Chapter 2 3-3. To notify the operator that the position of the frame is misaligned When the frame is moved by the following operation while the machine stops during embroidery, the right lamps at tension bases of all heads will light up in blue. Thus, the machine will notify the operator that the frame is not in the original position. 1. Manual frame travel 2. Return to the start position 3. Offset Return 4. Frame travel to an optional position After the frame is moved by the operation described above, pressing the stop switch will cause the frame to return to previous position (Automatic data point return function). This function is effective only when "Return frame after frame travel" is set to "Yes".(→p.152) [An example when using automatic data point return function] (1) Stop the machine during embroidery, and pull out the frame to the front. The right lamp will light up. Lit in blue Right lamp Right lamp Right switch Moving up the right switch will turn off the right lamps at all heads and make this function invalid during lighting up of the right lamp. To make it valid, move up the right switch again. RR01