Page 77 of 249

Embroidery starts 65 Chapter 4 SQ06 7-3. Countermeasure against thread breakage The machine will stop automatically. Besides, the thread breakage indicator lamp will be lit or blinking in red. Code No.291 or No.293 will be also displayed on the operation panel. Start the embroidery again by the following procedure. (1) Pass the upper thread, or change the under thread (bobbin case). (2) Perform Frame Back by some stitches for repair stitches. When starting the machine, repair stitches will be performed from the position where Frame Back is stopped. Lit: The upper thread has broken. (No. 291) Blinking: The under thread has broken. (No. 293) Thread breakage indicator lamp Threader (accessory) Bobbin case To attach to rotary hook