Issue link: https://docs.hic.us/i/1260917
Countermeasure when the machine stopped 193 1 2 3 4 5 6 7 8 9 10 11 Chapter 9 TP02 1-3. Stop due to malfunction It is displayed in red on the screen. It is caused by card, harnesses or communication error. If the below code numbers are displayed, consult the distributor. BC1 The design which you try to input is not found in design spooler. Check the condition of the design spooler. BC2 The same file name exists in the USB memory. Change the file name. BC5 Insufficient remaining capacity of the USB memory Replace with a USB memory with enough remaining capacity. BF1 When Network connection to host personal computer is performed, IP Address could not be obtained from DNS server Check IP address of DNS server. Correct "IP Setting.ini" file. Check operating condition of DNS server. BF2 There was some error in the contents of "IP Setting.ini" file for Network setting. Correct contents of "IP Setting.ini" file. 5B1 It is not possible to input data due to abnormal contents of configuration in TCF design. Check the design. 5C1 Data set was performed without Frame Origin Memory after installation of software. The machine was stopped during operation of Frame Origin Memory. Perform Frame Origin Memory. 5C2 Machine was started during moving up/down of Sequin device. Start the device after completion of up/down. 5C3 Setting error of Sequin device III Check the setting of panel. 5C6 General external device is operating. Operate the machine after general external device is stopped. No. Stop factor How to restore 311 Encoder A signal status does not change for 5 seconds. Motor or motor belt failure. Check the connection of encoder signal wire. Check the excitation of the main shaft driver. Check the motor or the motor belt. 312 Fixed position signal (Main shaft Z signal) does not change during operation. Press the E key. Check the connection of the main shaft motor or the photo-interrupter card. If it is not possible to recover from the trouble, replace the main shaft motor or the photo-interrupter card. No. Stop factor How to restore Information error of head number Setting is different from the actual number. [3C3] "Reset" >>E Code No. Stop factor