Issue link: https://docs.hic.us/i/1260917
Countermeasure when the machine stopped 195 1 2 3 4 5 6 7 8 9 10 11 Chapter 9 TP02 3B5 Communication error (between CPU card USB hub), power supply system error of 280 V or 24 V, abnormality of power supply card Check harness connection between CPU card and USB hub. Check and/or replace power supply card. Check and/or replace DC power supply. Wrong selection of model at installation of software Install the software again. 3B7 Communication error inside the controller, bad communication (between CPU card and switch card) Turn "OFF/ON" the power. Check harness connection between CPU card and switch card. Replace CPU card or switch card. 3B8 Impossible communication with Sequin device III Check the sequin controller card or connection. 3B9 Communication error of up/down color change driver (Sequin device III only). Check the sequin driver card (Occurred only when power is turned ON). 3BA Communication error with Sequin device III Check the sequin controller card or connection (Occurred only when power is turned ON). 3BF Remaining number of beads cannot be grasped. Check and/or replace the head card. 3C1 Contact error of the bar switch or start/stop switch, breakage of the switch harness, or bad connection of the connector Check the connector and the connecting terminal. Replace the limit switch/switch assembly. 3D6 There is abnormality in the program or in the CPU card. Check the CPU card. The software is not installed normally. Install the software. 3DB System RAM insufficient capacity Turn "OFF/ON" the power. Replace CPU card. 3DC Memory device error Turn "OFF/ON" the power. Install the software. Replace the DOM or CPU card. 3DD System installation error Install the software. Replace DOM or CPU card. 3DE External memory device error Turn "OFF/ON" the power. Check/replace the USB memory, or replace the CPU card. 6D1 File error of frame drive parameter Install the software. 6D2 Disconnection of communication line Turn "OFF/ON" the power. Check harness connection between CPU card and USB hub. Check and/or replace power supply card. Check and/or replace DC power supply. Install the software again. 6D3 Disconnection of USB communication line in I/O card, communication error Turn "OFF/ON" the power. Check connection of USB cable Check and/or replace power supply card. Check and/or replace DC power supply. Install the software again. No. Stop factor How to restore