214 Countermeasure when the machine stopped Chapter 9 QS07 292 Material feed error occurred at zigzag cording device. Check the material. Check the sensor card, harness etc. of zigzag cording device. 293 Under thread breakage is detected. Check under thread. 294 Absence of sequin material is detected (Sequin device III only). Check the material. 2B1 Network does not work normally. Check connecting status of cable, setting status of device such as personal computer. 2B3 Data exists in an end code. Correct design data. 2B4 Function code error 2B5 Sequin data error 2B7 Data set is not completed. Set data. 2BA Memory capacity exceeded Delete unnecessary design(s) registered in the memory. 2BB Available range to perform frame back was exceeded. Do not perform frame back any more. 2BC No design is registered in the memory at all. Register designs in the memory. The delete of design in process of embroidery was attempted. To perform memory delete of design in process of embroidery, perform data input of other data or perform data input of the same design again. Data edit was attempted during embroidery. Do not perform data edit during embroidery. 2BE Start and End codes are not set as a one pair in satin conversion, sequin, boring and low speed code. Set again so that start and end codes become as a pair. 2C1 Machine was started during setting of data edit or needle bar selection. Start the machine after ending the setting. 2C2 Setting for option is incorrect. Set correctly. 2C6 The machine was operated during working of bobbin changer. Do not operate the machine during working of bobbin changer. 2C7 Wrong password is input. After pressing E key, input the correct password. 2C8 Sleep mode key was pressed during trace. Press the E key. 2C9 Time was changed during setting of Password (Time-based Limit). Press the E key. 2CA The power is not turned "OFF/ON". Turn "OFF/ON" the power. 2CE Stop by safety device After removing the obstacle, press E key, then press the start switch. 2E2 Air pressure of the regulator has become lower than the rated value. Check the air compressor. Check the origin of air supply. 2E3 Power supply failed during operation. Perform power resume operation after turning ON the power. B01 Abnormality occurred in reading/writing. Copy design to a new USB memory and use it. No. Stop Factor How to restore

Articles in this issue

view archives of Service Documents - MX INSTRUCTION