Countermeasure when the machine stopped 206 Chapter 9 PT10 3BD MC Error of ID written to the card. Driver not for machine card is connected. Check/replace machine card. 3BD S Refer to 3BD (MC) described above. Driver not for the main shaft is connected. Check and/or replace the main shaft driver. 3BD X Refer to 3BD (MC) described above. Driver not for X-axis is connected. Check/replace the X-axis driver. 3BD Y Refer to 3BD (MC) described above. Driver not for Y-axis is connected. Check/replace the Y-axis driver. 3BF Remaining number of beads cannot be grasped. Check and/or replace the head card. 3C1 Contact error of the bar switch or start/stop switch, breakage of the switch harness, or bad connection of the connector Check the connector and the connecting terminal. Replace the limit switch/switch assembly. 3C3 Mis-setting of the number of heads in "Machine Type" Check the contents of setting. 3D6 There is abnormality in the program or in the CPU card. Check the CPU card. The software is not installed normally. Install the software. 3DB Lack of system RAM capacity Turn "OFF/ON" the power. Replace CPU card. 3DC Abnormality of memory device Turn "OFF/ON" the power. Install the software. Replace the DOM or CPU card. 3DD Abnormal system installation Install the software. Replace DOM or CPU card. 3DE Abnormality of external memory device Turn "OFF/ON" the power. Check/replace the USB memory, or replace the CPU card. 6D1 File error of frame drive parameter Install the software. 6D2 Disconnection of communication line Turn "OFF/ON" the power. Check harness connection between CPU card and USB hub. Check and/or replace power supply card. Check and/or replace DC power supply. Install the software again. 6D3 Disconnection of USB communication line in I/O card, communication error Turn "OFF/ON" the power. Check connection of USB cable Check and/or replace power supply card. Check and/or replace DC power supply. Install the software again. No. Stop Factor How to restore

Articles in this issue

view archives of Service Documents - TEMX INSTRUCTION 1.2015