142 Page P1 Chapter 9 G 9 Auto jump This is the setting to perform jump automatically when stitch length is longer than the setting value. There are two types of auto jumps, A (Split auto jump) and B (Batch auto jump). 10 Jump Convert This is the setting to trim thread and move the frame to next stitch when jump codes continue more than the set times, Setting range No: Auto jump is not performed. 2.0 to 9.9 mm: Automatic jump is performed. A: Split auto jump B: Batch auto jump 240 to 360°: Frame start timing Yes: R.P.M. Keep is performed. No: R.P.M. Keep is not performed. Example: Set stitch length to 5.0 mm, and set to A (Split auto jump). If B(Batch auto jump) was selected, press the icon T, and select Frame start timing and R.P.M. Keep. Setting range Yes: Jump convert is performed. (1 to 9 times) No: Jump convert is not performed. Example: Set consecutive jump codes to 6 times. 5.0 9Auto jump A G q r s t 5.0 A T Frame start timing Keep up R.P.M. No 260 Yes 6J 10Jump convert Yes Y 6 G QS11