230 Chapter 11 Adjusting height of the presser foot (Input of the password is necessary) 4. Adjusting height of the presser foot (Input of the password is necessary) Return the height of the presser foot to the correct height at shipment from the factory by using the accessory "Presser foot gauge". Perform this work when the actual height (figure B) of the presser foot lower dead point is different from the value (figure A) on the operation panel as shown below figures. To perform this work, input of the password is necessary. After inputing the password, the following operation will become possible until you turn ON the power again next time. For details, consult the distributor. [How to adjust] Example: Adjust the height of the presser foot of the third needle at the second head. (1) Perform Color Change to the third needle by operating on the operation panel. (2) Icon G (3) Press P5 twice. (4) Icon S Presser foot gauge 5.0 mm Presser foot setting 2 Lower dead point Stroke Timing Stroke mode 0.5 mm 0.5 mm A 5.0 mm 30 F/B L. D. point 3.0mm 0.5 mm Presser foot 2.0 mm Figure A FigureB If the right switch of the tension base is lowered twice, the presser foot will lower to the lower dead point. G 1 Auto Color Change (AC) Yes I P5 2 Functional limit level S RR04