34 Basic screen Chapter 3 QS04R 1-2. Design selection screen (Screen 2000) Select a design in the machine memory and perform the edit of design, the change of needle bar order, and setting of repeat. 1. Screen number (2000) 2. Design data stored in the machine memory (first layer directory) 3. Folder Design data can be stored in the folder. It is not possible to change folder name (Group1 to Group5). 4. Remaining number of machine memory (40,000,000 stitches) Remaining capacity is displayed as "%". If remaining capacity becomes 20% or less, remaining number of stitches will be displayed. 5. Return to screen 1010 6. USB memory screen(→p.35) 7. Design edit screen(→p.79) 8. Current needle bar setting(→p.52) 9. Screen of enlargement/reduction and repeat for design(→p.108) 10. Decide the data set 11. Rearrangement of designs None: Registering order Name: Alphabetical file name order Time: Updating order 12. Scroll the screen 13. Return the screen to P1 14. If the folder is selected, the screen will be returned to the "Main" screen. 15. Design size (embroidery space) 16. The number of steps 17. With setting for automatic offset 18. With setting for repeat 19. With setting for enlargement/reductio n of design 20. Memory number of the machine 1 2 3 2 [ CRO ] TAJIMA_W 14117 st. X: 121.5 mm Steps :11 5 7 8 9 10 11 Y: 135.1 mm 15 16 When there is no design in the memory, icons 7, 8 and 9 will not be displayed. 14 Selecting the design will switch it. 4 6 12 13 17 18 19 20 Free space Screen 1010 A Screen 2000