Page P2 143 Chapter 9 G 2. Page P2 [How to switch to page P2] 11 F.B./F.F. stitch Unit Set frame feed amount when performing Frame Back or Frame Forward by 11 stitches or more. 12 Auto F.B. after thread break detection This is the setting to perform Frame Back automatically at thread breakage. (1) Icon G (2) P2 (3) Page P2 Setting range: 1,3,5 stitches Example: Set feed amount to 5 stitches. Setting range Yes: Auto F.B. is performed. 0 to 9: Number of stitches performing Frame Back No: Auto F.B. is not performed. The number of stitches performing Frame Back is the total of this value and the value of "26, Upper thread detection" or "27. Under thread detection (unit)" based on the stop point of the machine. Example: Perform Frame Back by 4 stitches. G Yes 1 Auto Color Change (AC) i P2 11 F.B./F.F. Stitch unit 3 st. 11 F.B./F.F. Stitch unit 5 st. G 5 12 Auto F.B. after T. detection 4 st. Yes r G 4 QS11