Functions that must be used practically 27 Chapter 2 3. Functions that must be used practically 3-1. To insert return stitching at start of embroidery When the machine stops, raising the left switch of the tension base at desired head will cause the head to perform return stitching at next start of embroidery (1) When thread breakage is detected at 1 head only (2) When detecting thread breakage at plural heads This function will make the machine work regardless of the setting of parameter "23 Return stitch". (→p.149) Red Left switch Left lamp Red/Green Left lamp After starting the machine, return stitching will be performed at this head only. Raise the left switch once after Frame Back. Red Left switch Left lamp Red Left lamp Raise the left switch of either the second or the third head once after Frame Back. Red/Green Left lamp Red/Green Left lamp After starting the machine, return stitching will be performed at the plural heads. To cancel return stitching mode at this time, raise the left switch of either the second or the third head twice. The left lamp at both heads will be switched to light up in red. 3rd head 2nd head 3rd head 2nd head Return stitch mode QS04