How to use each part 15 Chapter 2 2-2. Emergency stop switch The emergency stop switch is equipped as a measure for safety. Pressing this switch during operation will turn OFF the power and stop the machine. At this time, the power switch will be switched to the middle position. [How to restore] When the main shaft stops at the fixed position, the machine will start up as usual. Since the code No.2E3 will not be displayed, execute "Power resume" manually after checking thread cast-off, etc.(→p.70) When the main shaft stops at other than the fixed position, the code No.2E3 will be displayed. After resetting, the screen "Power resume" will be displayed.(→p.16) (1) Turn the switch to the right. Lock will be released. (2) The power switch is set to "Middle position". Turn "OFF" → "ON" the power switch. At this moment, wait for 30 seconds or more. When performing this operation, do not put your hands etc. on the machine table. Moving the frame could injure you. Below operation panel Back of machine CAUTION ! RR01