Issue link: https://docs.hic.us/i/445658
152 Page P3 Chapter 9 G 28 Under thread detection (step ratio) Set the sensitivity of detection when under thread breaks by all needles in a batch or by needle bar unit. 29 Auto origin return This is the setting to return the frame to start position after embroidery is finished. 30 Return Frame after Frame Travel This is the setting to return the frame to the previous position by the bar switch or the start switch operation after moving the frame during embroidery. Setting range Any: All needles in a batch 1st to last needle: Needle bar No. 30 to 100: Step ratio of detection (%) Example: Set all needle bars to 60%. Setting range Yes: Start position is returned. No: Start position is not returned. Example: Yes Setting range Yes: The frame is returned to previous position. No: The frame is not returned to previous position. If "No" is selected, "Automatic data point return" will be invalid. In this case, the frame will not return and the embroidery will be started from the position after the frame moving by switch operation. Example: Yes 28Under thread detection (step ratio) 50 Any 30 100 Sensitivity High Low P Any G s t 60 29 Auto origin return Yes G Yes r Yes 30Return Frame after Frame Travel G Yes r QS11