Issue link: https://docs.hic.us/i/445658
154 Page P4 Chapter 9 G 34 Preset Halt by Data This is the setting to make the machine to stop automatically when the cumulative amount of frame travel is reached to setting value. 35 Preset Halt by Designs This is the setting to make the machine to stop automatically when the cumulative number of embroidery designs is reached. 36 Preset Halt by Lubrication This is the setting to stop the machine automatically when the number of stitches are reached to setting value. 37 Preset Halt (1stitch before end code) This is the setting to stop the machine automatically at the position where one stitch before embroidery end. Setting range: 0 to 99,999 cm Example: Stop at 1,000 cm. After stop, "1D2" will be displayed. Setting range: 0 to 999 designs Example: Stop at 50 designs. After stop, "1D2" will be displayed. Setting range: 0 to 990,000 stitches Example: Stop at 50,000 stitches. The setting value x 10,000 stitches is the number of stitch to stop. After stop working, "OIL" will be displayed. It is effective only when the set- ting of "9 Automatic lubrication system" of page P7 is "No". Setting range Yes: Automatic stop is performed. No: Automatic stop is not performed. If "Yes" is selected, it is possible to perform Frame Back after stop of the machine. Example: Yes 34 Preset Halt by Data 1000 G 1 0 0 0 35 Preset Halt by Designs 50 G 5 0 36 Preset Halt by Lubrication 5 x G 5 37Preset Halt (1st before end code) Yes G Yes r QS11