170 Page P7 Chapter 9 G 5 Frame start timing (Input of the password is necessary) Set the main shaft angle where the frame starts moving. When changing the value, consult the distributor. Some operating condition could cause occurrence of bad effect in embroidery. Setting range 280 to 310: Frame start timing Example: 285° CAUTION ! 5Frame Start Timing 285 280° 310° High speed [Thread tension] Weak Low speed [Thread tension] Strong [Stitch length] Narrow G q r 285 QS11