207 Chapter 11 Troubleshooting 1C3 Halt by input of external stop signal Machine stopped by the stop signal from an external device. Continue the operation of the machine if needed. 1C4 Stop by switch operation of tension base M/C stopped by the change of tension base switch from Clutch to Normal during color change SQ/ Zigzag cord. Perform "Start operation" to continue the operation of machine if needed. 1C5 Installation interrupted. Software installation was interrupted by operator s operation. Press reset key and select Retry. 1D1 Halt at Frame Back start point Machine stopped by the halt setting at the start point of embroidery for all heads after Frame Back operation. Perform "Start operation" to continue the embroidery. 1D2 Preset halt Machine stopped by the preset halt setting. Reset by pressing the reset key. Perform "Start operation" to continue the embroidery. 1D4 Pause (Temporary halt) by data preparation "Now processing" is displayed. Wait until the indication goes out. 1D5 Preset halt (Lochrose) Machine stopped by the preset halt (Lochrose) setting. Reset by pressing the reset key. Check/ replace the beads. Perform "Start operation" to continue the embroidery. 1D6 Receipt of PCB-reset request Transmit a message to reset request in the middle of embroidery. "Now processing" is displayed. Wait until the indication goes out. 211--01 Fixed position signal error Machine stopped at other than the fixed position. Return the main shaft to the fixed position. Adjust encoder/encoder Z signal. 211--02 Fixed position signal error Machine stopped at other than the fixed positions of main shaft and needle position. Return the main shaft/needle position to the fixed position. Adjust the encoder/encoder Z signal. 211--03 Fixed position signal error Machine stopped at other than the fixed position of main shaft during power resume. Adjust the encoder/the encoder Z signal. Initializing the error code causes frame origin search starts after the main shaft moves to the fixed position automatically. 211--04 Fixed position signal error Encoder Z signal cannot be detected due to poor encoder adjustment even when the main shaft is at the fixed position. Check the encoder. Adjust the encoder so that the mechanically fixed position synchronize to the encoder Z signal correctly. 212 In the state of needle bar lowered Needle bar is descending. Move needle bar up and operate the machine. 213 Lower dead point error Machine is stopping at the lower dead point. Move needle bar up and operate the machine. Cord Stop factor Corrective Action QS08