Service Documents

TMARK INSTRUCTION 7.2014

Issue link: https://docs.hic.us/i/445658

Contents of this Issue

Navigation

Page 196 of 261

182 Page P8 Chapter 9 G 5 Machine log data acquisition (Input of the password is necessary) Get the operation logs and the communication records. This function is for analyzing cause of some trouble of the machine. When your distributor asks you to get log datas, send datas to your distributor saving log data information in USB memory by the following operation. Writing Setting data saved in USB memory will be written into the machine memory by the operation of "Backup". Set USB memory, in which the setting data is saved, to the operation panel before the operation, and select icon B. It is possible to check repeatability with writing the setting data of the machine, which had trouble, to another machine by this function. A software version of the embroidery machine which performs "Writing" should be same as that of the machine which performed "Backup". Example: Backup 1. Set the USB memory. 2. Select the backup. Setting range Save on operation panel Save the log datas into a CF (Compact Flash Memory) inside of the operation panel for 50 times. The log datas exceeding 50 times will be overwritten. It is not possible to take out any data from a CF. Save in USB. Save the log datas saved in CF and log datas acquired at this time into USB memory. Example: Save in USB G q r Backup 5 Machine log data acquisition G q r Save in USB. Set USB mem- ory QS11

Articles in this issue

view archives of Service Documents - TMARK INSTRUCTION 7.2014