Issue link: https://docs.hic.us/i/445658
Page P8 183 Chapter 9 G 6 Display of main shaft stop position (Input of the password is necessary) It displays whether the current main shaft angle is within the range of fixed position. 7 Display of needle position angle (Input of the password is necessary) Display the value of the color change potentiometer and set the ball-screw type color change system. If icon q or r is selected, color change will be performed. Do not put your hands etc. near the needle bar case. You could be injured. Example: Display the value of color change potentiometer. 6 Display of main shaft stop position Within fixed position Out of fixed position, or Stop at Lower Dead CAUTION ! 7 Display of needle position angle 1. Value of potentiometer of needle bar selected currently It is normal when the value at the first needle is "127". 2. Correcting value of color change position After Memory initialize, set the value of "Correction of Color interval" mentioned on the label stuck on the operation panel stand. T 1 1 Color Change 127 2 If icon q or r is selected, color change will be per- formed. QS11