184 Page P8 Chapter 9 G 8 Time for detect power failure (Input of the password is necessary) Set the machine movement when the power is shut off momentarily. 9 Main Shaft Brake (Input of the password is necessary) This is the setting to apply/not to apply the brake of Main shaft motor at stop of the machine. 12 Manual frame travel speed (Input of the password is necessary) Perform fine tuning of Frame travel speed when Manual frame travel is performed. Setting range Short When the power is shut off momentarily, the machine will stop at the fixed position. Long It is possible to embroider without stopping the machine even if the power is shut off momentarily in longer time than "Short". However, when the power is shut off during some period of time, the machine will stop. In this case, the design in the middle of embroidery cannot be guaranteed. Example: Shortly Setting range Yes: Apply the brake. (Fixing main shaft) No: Do not apply the brake. (Release of fixing main shaft) If "No" is selected, it is possible to turn the main shaft by hand with the power ON. Example: No Setting range Middle speed: 30 to 70 mm/second High speed: 80 to 150 mm/second Example: Set Middle speed to "60". 8 Time for detect power failure Short G q r Short 9 Main Shaft Brake No G No q 12 Manual frame travel speed 50 Middle speed 100 High speed G q r 60 Middle speed QS11