Issue link: https://docs.hic.us/i/1518964
Chapter 4 Maintenance 4-6 1 With the screen in local mode, select [MENU] > [MAINTENANCE], and then press the [ENTER] key. • The Maintenance menu is displayed. 2 Select [STATION MAINT.] > [CARRIAGE OUT] > [HEAD MAINT.], and then press the [ENTER] key. • The carriage moves to the maintenance space. 3 Open the maintenance cover. 4 Wipe off any ink adhering to the sides of the head and under the carriage. • Wipe off any ink, dust, ink dry matter and adhering using a cleaning stick moistened with maintenance liquid. Wipe off the maintenance liquid to make sure none remains. • Be careful to avoid leaving fragments from the cleaning stick behind when cleaning. These fragments will increase the risk of ejection fail- ures (e.g., nozzle clogging or deflection). • Never rub head nozzles. M R 1 4 8 Z Z M R 1 4 8 Z Z Clean the end side of head and the guard plate edge (the areas indicated in red) using a cleaning stick. Never touch the nozzle surface! Clean with a cleaning stick, tweezers, or cloth. [TxF150-75] M R 1 4 8 Z Z Clean the end side of head and the guard plate edge (the areas indicated in red) using a cleaning stick. Never touch the nozzle surface! Clean with a cleaning stick, tweezers, or cloth. [TxF300-75]