4-17 1 2 2 4 5 6 Chapter 4 Maintenance 3 Attach the exhaust box in its original position. • Engage the tabs at the rear of the exhaust box onto the machine, and then push in the front side. Replacing the CP pad set If the CP pad set is very dirty or if ink drips onto the media, replace with a new cap absorber. 1 With the screen in local mode, select [MENU] > [MAINTENANCE], and then press the [ENTER] key. • The Maintenance menu is displayed. 2 Select [STATION MAINT.] > [CARRIAGE OUT] > [STATION MAINT.], and then press the [ENTER] key. • The carriage moves over the platen. 3 Remove the CP pad set. • Push up the two tabs at the front to remove the cap absorber. 4 Attach the new CP pad set. • Push the tabs of the CP pad set into the slits at the rear of the C slider, then insert the tabs at the front. 5 After replacement, manually return the wiper to the rear. 6 Turning On the Power • Check to confirm that the carriage returns to the station. Replacing pinch rollers Replace the pinch roller with a new pinch roller if it is dirty or severely worn out. 1 Raise the clamp lever. 2 Remove the O-rings holding the pinch rollers. Exhaust fan filter Exhaust fan BOX CP pad set Illustration:TxF150-75 • Turn off the main power supply and unplug the power cable before carrying out maintenance. • Do not use maintenance liquids, or alcohol, etc. • The O-rings are small. Be careful to avoid drop- ping them into the product interior. CP pad assembly Tab C slider Press to engage the tabs