Issue link: https://docs.hic.us/i/1518964
Chapter 4 Maintenance 4-8 4 Press the [ENTER] key. • Pump tube (ink discharge channel below the cap) washing starts. Cleaning head nozzles 1 With the screen in local mode, select [MENU] > [MAINTENANCE], and then press the [ENTER] key. • The Maintenance menu is displayed. 2 Select [STATION MAINT.] > [NOZZLE WASH], and then press the [ENTER] key. • The carriage moves over the platen. 3 Clean the wiper and bracket, and then press [ENTER] key. • P.4-4 [Cleaning the wiper and cap] 4 Clean the cap rubber and press the [ENTER] key. • P.4-4 [Cleaning the wiper and cap] • At this time, the channel is cleaned automatically. 5 Press the [ENTER] key. • The carriage moves over the platen, and the cap is filled with maintenance liquid (if the maintenance liquid cartridge is usable). • Check whether the cap is filled with maintenance liquid. • Pressing the [FUNC2] key enables additional filling with maintenance liquid. 6 Set the leaving time, and then press the [ENTER] key. • Setting value: 1–99 (in 1-minute increments) • The nozzles are washed. The machine draws maintenance liquid from the cap. • Cleaning is performed automatically after nozzle washing. • If the maintenance liquid cartridge is usable, suck maintenance liquid into a dropper and fill up the cap with it. Fill up the cap with maintenance liquid on the verge of overflow from the cap. Illustration:TxF150-75 Illustration:TxF150-75 • If the maintenance liquid cartridge is usable, suck maintenance liquid into a dropper and fill up the cap with it. Fill up the cap with mainte- nance liquid on the verge of overflow from the cap. • If the nozzle clogging is not corrected even after you use this function several times, contact your dealer, or sales office (service call). Illustration:TxF150-75