Mimaki

TXF Operation Manual

Issue link: https://docs.hic.us/i/1518964

Contents of this Issue

Navigation

Page 88 of 99

Chapter 5 Troubleshooting 5-9 1 2 2 2 5 SYSTEM HALT There is remaining print data. • Clear the data ( P.2-12). An error occurred in the mounted heads. • Temporarily turn off the main power supply, and then turn it on again. If the message appears again, contact your dealer, or our sales office or call center. The media is not wide or long enough for printing. • Switch to media that is wide or long enough. • If media width has narrowed because you have moved the origin, move the origin to the right to widen the effective media width. An error occurred with the main PCB FROM. • Temporarily turn off the main power supply, and then turn it on again. If the message appears again, contact your dealer, or our sales office or call center. Message Corrective action • Temporarily turn off the main power supply, and then turn it on again. If the message appears again, check the number and contact your dealer, or our sales office or call center. ("000" represents the error number.) • Perform cleaning around the wiper. • Temporarily turn off the main power supply, and then turn it on again. If the message appears again, check the number and contact your dealer, or our sales office or call center. Message Cause Corrective action ERROR 902 DATA REMAIN ERROR 90d NO HEAD SELECT ERROR 90f PRINT AREA SHORT ERROR 04 PARAM ROM SYSTEM HALT (*) 000: MESSAGE SYSTEM HALT (*) 406 : WIPER ORG

Articles in this issue

view archives of Mimaki - TXF Operation Manual